Air Particle Counter

Experience the excellence of our Air Particle Counter, a prime solution engineered with over 49.0 years of expertise to deliver the perfect balance of precision and efficiency for your air particle measurement needs. As a trusted service provider, manufacturer, and supplier, we offer a trending range of products, including the Co2 Incubator Validation, Lasair Particle Counter, Climet Ci450 Particle Counter, Lasair Ii 110 0.1 Micron Particle Counter (ideal for Virus Detection), and Climet Ci500 Particle Counter. Designed for optimum accuracy and reliability, our Air Particle Counter ensures unmatched performance in particle detection and monitoring applications, making it a superior choice over competitors. Powered by advanced technology, it provides early contamination alerts, facilitates excellent environmental compliance, offers user-friendly interfaces, ensures real-time data accuracy, and boasts a robust design for long-term usability. Get unparalleled operational efficiency with options tailored for diverse industries, all while availing competitive discounts. With a supply ability across All India, our commitment to quality and customer satisfaction makes our product the perfect solution for ensuring clean and safe environments. Choose our Air Particle Counter for prime performance and unmatched reliability in leading-edge particle detection.

Co2 Incubator Validation

MOQ : 1 Unit

  • Equipment Type
  • CO2 Incubator Validation Unit
  • Accuracy
  • 0.1% CO2
  • Application
  • Validation of CO2 incubator performance
  • Automation Grade
  • Automatic
  • Capacity
  • Up to 170 L
  • Control Mode
  • Microprocessor based control
  • Display Type
  • LCD digital display
  • Features
  • Data logging, user friendly software, over temperature alarm
  • Frequency
  • 50 Hz
  • Gas Pressure
  • 0.5 to 1.0 bar
  • Humidity
  • Up to 95% RH
  • Interface Type
  • USB/RS232
  • Machine Weight
  • Less than 8 kg
  • Max Height
  • 450 mm
  • Measuring Range
  • 0-20% CO2
  • Mounting Type
  • Table Top
  • Number of Specimens
  • 1 to 3
  • Operating Voltage
  • 230 V AC
  • Port Size
  • 1/8 inch
  • Power Supply
  • 230 V AC, 50 Hz
  • Resolution
  • 0.01% CO2
  • Response Time
  • Less than 10 seconds
  • Specimen Size
  • Minimal size requirement: 10 x 10 mm
  • Temperature
  • +5C to +50C
  • Test Range
  • 0.1% - 20%
  • Test Speed
  • 1 - 200 mm/min
  • Test Stroke
  • 100 mm
  • Test Width
  • 150 mm
  • Usage
  • Laboratory, Research and Quality Control

Lasair Particle Counter

MOQ : 1 Unit

  • Equipment Type
  • Portable Particle Counter
  • Accuracy
  • 10% for counting efficiency
  • Application
  • Airborne particle monitoring in cleanrooms and controlled environments
  • Automation Grade
  • Automatic data logging
  • Capacity
  • 2.83 LPM (1.0 CFM) standard flow
  • Control Mode
  • Touchscreen direct operation
  • Display Type
  • Large color touchscreen
  • Features
  • Battery-powered, data storage, print capability, alarm, user-friendly interface
  • Frequency
  • 50/60 Hz
  • Humidity
  • 0-95% RH non-condensing
  • Interface Type
  • USB, Ethernet, RS-232
  • Machine Weight
  • Approx. 5 kg
  • Measuring Range
  • 0.3-25.0 m
  • Mounting Type
  • Handheld/portable
  • Operating Voltage
  • 100-240 VAC
  • Port Size
  • Sample Inlet: 1/4 ID
  • Power Supply
  • 100-240 VAC, 50/60 Hz
  • Resolution
  • 0.1 m
  • Response Time
  • Instantaneous display
  • Temperature
  • 10C to 35C (Operating)
  • Test Range
  • 0.3-25.0 m particle size
  • Test Speed
  • Real-time sampling, user-selectable flow rate
  • Usage
  • Cleanroom monitoring, pharmaceutical, and semiconductor industries

Climet Ci500 Particle Counter

MOQ : 1 Unit

  • Equipment Type
  • Handheld Particle Counter
  • Accuracy
  • 10% (per ISO 21501-4)
  • Application
  • Cleanroom environmental monitoring, pharmaceutical and electronics manufacturing
  • Automation Grade
  • Semi-Automatic
  • Capacity
  • 1000 sample record storage
  • Control Mode
  • Manual/Automatic
  • Display Type
  • Digital LCD Display
  • Features
  • Battery Operated, Lightweight, Data Logging, ISO 21501-4 Compliant
  • Frequency
  • 50/60 Hz
  • Humidity
  • 0-95% RH (non-condensing)
  • Interface Type
  • USB, RS-232
  • Machine Weight
  • 3.2 kg
  • Measuring Range
  • 0.3 m - 5.0 m
  • Mounting Type
  • Handheld/Benchtop
  • Number of Specimens
  • Single channel sampling
  • Operating Voltage
  • 100-240 V, 50/60 Hz
  • Port Size
  • 0.1 cfm (2.83 LPM) sample flow rate
  • Power Supply
  • 100-240 V AC, 50/60 Hz
  • Resolution
  • 0.1 m
  • Response Time
  • Less than 1 second
  • Temperature
  • Operating: 0C to 35C
  • Test Range
  • 0.3 to 5.0 micron
  • Usage
  • Airborne Particle Counting

Climet Ci450 Particle Counter

MOQ : 1 Unit

  • Equipment Type
  • Portable Particle Counter
  • Accuracy
  • +/-10% at 0.5 m
  • Application
  • Airborne Particle Monitoring in Cleanrooms
  • Automation Grade
  • Semi-Automatic
  • Capacity
  • Continuous sampling
  • Control Mode
  • Manual and Remote
  • Display Type
  • High-resolution color touchscreen
  • Features
  • Data logging, Audible alarm, ISO 21501-4 compliant
  • Frequency
  • 50/60 Hz
  • Gas Pressure
  • 0.7 bar (max allowable)
  • Humidity
  • 0-95% non-condensing
  • Interface Type
  • Ethernet, USB, RS-232
  • Machine Weight
  • 5.5 kg
  • Measuring Range
  • 0.3 to 25 m
  • Mounting Type
  • Portable/Handheld
  • Operating Voltage
  • 100-240V AC
  • Port Size
  • Inlet: 3/8 OD
  • Power Supply
  • 100-240V AC, 50/60 Hz
  • Resolution
  • 0.1 m
  • Response Time
  • < 1 second
  • Temperature
  • 0C to 40C
  • Test Speed
  • 1 CFM, 50 LPM
  • Usage
  • Pharmaceutical, Biotechnology, Electronics, Hospitals

Lasair Ii 110 0.1 Micron Particle Counter (Virus Detection)

MOQ : 1 Unit

  • Equipment Type
  • Portable Airborne Particle Counter
  • Accuracy
  • 10% at 0.1 m
  • Application
  • Virus & particle detection in cleanrooms, laboratories
  • Automation Grade
  • Automatic and manual operation
  • Capacity
  • 1000 records & 2500 sample points
  • Control Mode
  • Touchscreen control & programmable routines
  • Display Type
  • Backlit touchscreen with graphic display
  • Features
  • HEPA filtered exhaust, real-time data, printer output, multi-language support, alarm alerts, modular design
  • Frequency
  • 50 Hz/60 Hz
  • Gas Pressure
  • Atmospheric
  • Hardness
  • Impact-resistant polymer body
  • Humidity
  • 0-95% RH, non-condensing
  • Interface Type
  • RS-232, USB, Ethernet
  • Machine Weight
  • 8.1 kg (17.8 lbs)
  • Max Height
  • 240 mm (instrument height)
  • Measuring Range
  • 0.1 m to 5.0 m
  • Mounting Type
  • Portable/benchtop
  • Number of Specimens
  • Supports multi-location sequential testing
  • Operating Voltage
  • 100-240V AC
  • Port Size
  • Inlet: 1/4 (6 mm) ID tubing
  • Power Supply
  • 100-240 VAC, 50-60 Hz, 100 VA max
  • Resolution
  • 0.1 m increments
  • Response Time
  • Immediate (real time data logging)
  • Specimen Size
  • Sample flow: 1.0 cfm (28.3 L/min)
  • Temperature
  • 10 to 35C (operating)
  • Test Range
  • 0.1 to 5.0 m
  • Test Speed
  • Up to 50 locations/hour (typical)
  • Test Width
  • Customizable scanning width by probe movement
  • Usage
  • Airborne particulate and virus detection

Ci-1054 100 Lpm Climet Particle Counter

MOQ : 1 Piece

  • Equipment Type
  • Portable Particle Counter
  • Accuracy
  • 10% for counting efficiency
  • Application
  • Cleanroom particle monitoring
  • Automation Grade
  • Automatic
  • Capacity
  • Flow Rate 100 L/min
  • Control Mode
  • Automatic Touchscreen Operation
  • Display Type
  • Color Touchscreen Display
  • Features
  • Battery operation, stainless steel enclosure, built-in printer
  • Frequency
  • 47-63 Hz
  • Humidity
  • 20-95% RH non-condensing
  • Interface Type
  • USB, Ethernet, RS-232
  • Machine Weight
  • Approx. 13.6 kg
  • Measuring Range
  • 0.3-25 m
  • Mounting Type
  • Portable or stationary
  • Operating Voltage
  • 100-240 V AC
  • Port Size
  • 1 inch tri-clamp
  • Power Supply
  • 100-240 V AC, 47-63 Hz
  • Resolution
  • 0.1 m
  • Response Time
  • Immediate/Real-time
  • Temperature
  • 10 to 35C operating
  • Test Range
  • 0.3 to 25 m particle size
  • Usage
  • Environmental monitoring, pharmaceutical, biotech

Air Velocity And Acph Test

MOQ : 1 Unit

  • Equipment Type
  • Air Velocity and ACPH Tester
  • Accuracy
  • 2% of reading
  • Application
  • Air flow and air change test in HVAC systems
  • Automation Grade
  • Automatic
  • Control Mode
  • Automatic
  • Display Type
  • Digital LCD
  • Features
  • Portable, lightweight, high sensitivity
  • Frequency
  • 50 Hz
  • Gas Pressure
  • 0.5 MPa
  • Humidity
  • 10-90% RH
  • Interface Type
  • RS232
  • Machine Weight
  • 18 kg
  • Measuring Range
  • 0.2-30 m/s
  • Mounting Type
  • Desk or tripod mount
  • Number of Specimens
  • 1
  • Operating Voltage
  • 220V AC
  • Port Size
  • 80 mm
  • Power Supply
  • AC 220V, 50 Hz
  • Resolution
  • 0.01 m/s
  • Response Time
  • 1 second
  • Specimen Size
  • 300 x 300 mm
  • Temperature
  • 0-50C
  • Test Range
  • 0.2-30 m/s
  • Test Speed
  • 0.2 to 30 m/s
  • Test Stroke
  • Adjustable
  • Test Width
  • 600 mm
  • Usage
  • Laboratory, Industrial


arrow