Ci-1054 100 Lpm Climet Particle Counter
Ci-1054 100 Lpm Climet Particle Counter

Ci-1054 100 Lpm Climet Particle Counter

MOQ : 1 Piece

Ci-1054 100 Lpm Climet Particle Counter Specification

  • Features
  • Battery operation, stainless steel enclosure, built-in printer
  • Automation Grade
  • Automatic
  • Display Type
  • Color Touchscreen Display
  • Temperature
  • 10 to 35C operating
  • Equipment Type
  • Portable Particle Counter
  • Humidity
  • 20-95% RH non-condensing
  • Test Range
  • 0.3 to 25 m particle size
  • Response Time
  • Immediate/Real-time
  • Port Size
  • 1 inch tri-clamp
  • Application
  • Cleanroom particle monitoring
  • Interface Type
  • USB, Ethernet, RS-232
  • Measuring Range
  • 0.3-25 m
  • Accuracy
  • 10% for counting efficiency
  • Resolution
  • 0.1 m
  • Operating Voltage
  • 100-240 V AC
  • Mounting Type
  • Portable or stationary
  • Frequency
  • 47-63 Hz
  • Power Supply
  • 100-240 V AC, 47-63 Hz
  • Usage
  • Environmental monitoring, pharmaceutical, biotech
  • Capacity
  • Flow Rate 100 L/min
  • Machine Weight
  • Approx. 13.6 kg
  • Control Mode
  • Automatic Touchscreen Operation
  • Channels
  • 6 User-selectable particle size channels
  • Compliance Standards
  • ISO 21501-4, CE Certified, RoHS
  • Inlet Probe
  • Isokinetic sampling probe included
  • Alarm Function
  • Built-in audible and visual alarms
  • HEPA Filter
  • Exhaust air HEPA filtered
  • Enclosure Material
  • Stainless steel
  • Data Storage
  • Up to 10,000 records in memory
  • Battery Life
  • Up to 8 hours operation
  • Printer
  • Internal thermal printer
  • Data Output
  • USB, network, and RS232 data transfer
 

Ci-1054 100 Lpm Climet Particle Counter Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About Ci-1054 100 Lpm Climet Particle Counter



Order the Crackerjack Ci-1054 100 Lpm Climet Particle Counter today and revolutionize your cleanroom monitoring experience! This splendiferous device features customizable six user-selectable channels, built-in visual and audible alarms, and a spectacular internal thermal printer. With robust stainless steel construction, the Ci-1054 offers up to 8 hours of battery operation while storing 10,000 records. Easily transfer data via USB, network, or RS232. Shop now to experience immediate, real-time response and unmatched automation. Perfect for pharmaceutical, biotech, and environmental monitoring sectors across India!

Advanced Features & Versatile Commercial Benefits

The Ci-1054 100 Lpm Climet Particle Counter stands out with its isokinetic sampling probe, HEPA-filtered exhaust, and vivid color touchscreen. Enjoy precise 0.1 m resolution over a 0.3-25 m test range, automatic operation, and flexible mounting-portable or stationary. Its compliance with ISO 21501-4, CE, and RoHS standards ensures reliability, making it ideal for pharmaceuticals, biotechnology, or environmental monitoring, delivering confidence, accuracy, and efficiency in demanding commercial environments.


Premium Certification, Sample Policy & Market Value

We uphold a premium sample policy for the Ci-1054 Particle Counter, designed to help you assess its market value and exceptional performance. Samples are dispatched swiftly to ensure your satisfaction and informed purchasing experience. Certified to ISO 21501-4, CE, and RoHS standards, the product underscores reliability and safety. Request a sample today to appreciate the full spectrum of its features before making a substantial investment in your facility's future.


FAQ's of Ci-1054 100 Lpm Climet Particle Counter:


Q: How does the Ci-1054 Particle Counter support cleanroom environmental monitoring?

A: The Ci-1054 offers real-time particle detection with customizable channels and immediate alarms, making it ideal for ensuring ISO-compliant environmental conditions within cleanrooms, pharmaceuticals, and biotech facilities.

Q: What are the commercial advantages of this portable particle counter?

A: Its lightweight, portable design, stainless steel enclosure, built-in printer, and high storage capacity make it a reliable, all-in-one tool for demanding commercial monitoring and compliance applications.

Q: Where can I use the Ci-1054 Particle Counter effectively?

A: This device can be effectively used in environments requiring strict particle control, such as pharmaceutical production, biotechnology labs, cleanrooms, and environmental monitoring operations.

Q: What certifications does the Ci-1054 meet, and how do they benefit me?

A: The Ci-1054 is ISO 21501-4, CE, and RoHS certified, ensuring global compliance, safety, and market acceptance, thus providing peace of mind for auditors and regulatory inspections.

Q: How can I obtain a sample or request a demonstration unit?

A: You can request samples or arrange a demonstration by contacting us directly. Our premium sample policy ensures prompt dispatch and allows you to evaluate the market value and suitability before finalizing your order.

Q: What is the process for data transfer and storage?

A: The Ci-1054 stores up to 10,000 records, which can be conveniently downloaded via USB, Ethernet, or RS232 for efficient data management and reporting.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Air Particle Counter Category

Co2 Incubator Validation

Co2 Incubator Validation

Minimum Order Quantity : 1 Unit

Accuracy : 0.1% CO2

Measuring Range : 020% CO2

Usage : Laboratory, Research and Quality Control

Application : Validation of CO2 incubator performance

Interface Type : USB/RS232

Lasair Ii 110 0.1 Micron Particle Counter (Virus Detection)

Lasair Ii 110 0.1 Micron Particle Counter (Virus Detection)

Minimum Order Quantity : 1 Unit

Accuracy : 10% at 0.1 m

Measuring Range : 0.1 m to 5.0 m

Usage : Airborne particulate and virus detection

Application : Virus & particle detection in cleanrooms, laboratories

Interface Type : RS232, USB, Ethernet

Air Velocity And Acph Test

Air Velocity And Acph Test

Minimum Order Quantity : 1 Unit

Accuracy : 2% of reading

Measuring Range : 0.230 m/s

Usage : Laboratory, Industrial

Application : Air flow and air change test in HVAC systems

Interface Type : RS232

Climet Ci450 Particle Counter

Climet Ci450 Particle Counter

Minimum Order Quantity : 1 Unit

Accuracy : +/10% at 0.5 m

Measuring Range : 0.3 to 25 m

Usage : Pharmaceutical, Biotechnology, Electronics, Hospitals

Application : Airborne Particle Monitoring in Cleanrooms

Interface Type : Ethernet, USB, RS232



arrow