Air Velocity And Acph Test
Air Velocity And Acph Test

Air Velocity And Acph Test

MOQ : 1 Unit

Air Velocity And Acph Test Specification

  • Test Range
  • 0.2-30 m/s
  • Interface Type
  • RS232
  • Features
  • Portable, lightweight, high sensitivity
  • Automation Grade
  • Automatic
  • Specimen Size
  • 300 x 300 mm
  • Equipment Type
  • Air Velocity and ACPH Tester
  • Humidity
  • 10-90% RH
  • Display Type
  • Digital LCD
  • Temperature
  • 0-50C
  • Port Size
  • 80 mm
  • Number of Specimens
  • 1
  • Gas Pressure
  • 0.5 MPa
  • Resolution
  • 0.01 m/s
  • Response Time
  • 1 second
  • Frequency
  • 50 Hz
  • Mounting Type
  • Desk or tripod mount
  • Operating Voltage
  • 220V AC
  • Power Supply
  • AC 220V, 50 Hz
  • Application
  • Air flow and air change test in HVAC systems
  • Accuracy
  • 2% of reading
  • Measuring Range
  • 0.2-30 m/s
  • Usage
  • Laboratory, Industrial
  • Machine Weight
  • 18 kg
  • Test Speed
  • 0.2 to 30 m/s
  • Test Width
  • 600 mm
  • Test Stroke
  • Adjustable
  • Control Mode
  • Automatic
  • Alarm
  • Over limit audible alarm
  • Protection Level
  • IP54
  • Data Output
  • USB/RS232
  • Sampling Method
  • Continuous / Spot Sampling
  • Sensor Type
  • Hot Wire Anemometer
  • Operating Environment
  • Indoor/Outdoor
  • Air Change Calculation
  • Yes, ACPH auto calculation
  • Battery Backup
  • Up to 8 hours
  • Calibration
  • Factory calibrated, user adjustable
  • Data Logging
  • Built-in memory for up to 1000 records
 

Air Velocity And Acph Test Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 7 Days
 

About Air Velocity And Acph Test



Discover the must-have Air Velocity and ACPH Tester-an affordable, premier solution for precise airflow and air change measurements in HVAC systems. Engineered for masterful performance, it boasts a lavish digital LCD display and advanced hot wire anemometer sensor for accurate readings (0.2-30 m/s with 2% accuracy). Continuous or spot sampling, built-in data logging for up to 1000 records, and up to 8 hours of battery backup combine efficiency and convenience. Automatic control, ACPH calculation, and robust IP54 protection complete this portable, lightweight, factory-calibrated device. A new standard in testing for laboratories and industry.

Versatile Application Surface and Usage

The Air Velocity and ACPH Tester is widely utilized by HVAC professionals, laboratory technicians, and industrial operators. Its specific use lies in accurately assessing air flow and air change per hour on various application surfaces such as ducts, vents, and indoor spaces. This equipment is essential both for general air quality surveys and specialized air balancing in automation systems. Its adjustable testing width and automatic control make it indispensable for ensuring optimal indoor environments and comprehensive environmental audits.


Export Reach, Delivery, and Certifications

Our Air Velocity and ACPH Tester enjoys strong sale price attractiveness across premier export markets including Asia, Africa, and the Middle East. Every shipment is supported by reliable logistics and timely delivery, with a standard lead time of 7-10 business days. Fully certified for industrial and laboratory use, it meets rigorous quality and calibration standards. As a reputed manufacturer and supplier from India, we guarantee swift, secure logistics and consistently prompt service for all orders.


FAQ's of Air Velocity And Acph Test:


Q: How does the Air Velocity and ACPH Tester perform data logging?

A: The tester includes a built-in memory capable of storing up to 1000 records, making it simple to track and review airflow and ACPH measurements over time.

Q: What is the benefit of using continuous or spot sampling with this device?

A: Continuous or spot sampling allows users to tailor their testing approach for either ongoing monitoring or quick spot checks, providing flexibility for various HVAC and laboratory settings.

Q: When should I use the automatic control mode?

A: Automatic control mode should be utilized when consistent, repeatable testing is needed-ideal for laboratories and industrial processes requiring high accuracy and minimal manual intervention.

Q: Where can this air velocity tester be operated safely?

A: With its IP54 protection level, the tester can be used in both indoor and outdoor environments where dust and water spray might be present, ensuring durability during real-world applications.

Q: What certifications does your Air Velocity and ACPH Tester have?

A: Our tester is factory calibrated, user-adjustable, and adheres to stringent quality and safety standards necessary for industrial, laboratory, and export requirements.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Air Particle Counter Category

Co2 Incubator Validation

Co2 Incubator Validation

Minimum Order Quantity : 1 Unit

Accuracy : 0.1% CO2

Measuring Range : 020% CO2

Application : Validation of CO2 incubator performance

Operating Voltage : 230 V AC

Power Supply : 230 V AC, 50 Hz

Lasair Ii 110 0.1 Micron Particle Counter (Virus Detection)

Lasair Ii 110 0.1 Micron Particle Counter (Virus Detection)

Minimum Order Quantity : 1 Unit

Accuracy : 10% at 0.1 m

Measuring Range : 0.1 m to 5.0 m

Application : Virus & particle detection in cleanrooms, laboratories

Operating Voltage : 100240V AC

Power Supply : 100240 VAC, 5060 Hz, 100 VA max

Climet Ci500 Particle Counter

Climet Ci500 Particle Counter

Minimum Order Quantity : 1 Unit

Accuracy : 10% (per ISO 215014)

Measuring Range : 0.3 m 5.0 m

Application : Cleanroom environmental monitoring, pharmaceutical and electronics manufacturing

Operating Voltage : 100240 V, 50/60 Hz

Power Supply : 100240 V AC, 50/60 Hz

Climet Ci450 Particle Counter

Climet Ci450 Particle Counter

Minimum Order Quantity : 1 Unit

Accuracy : +/10% at 0.5 m

Measuring Range : 0.3 to 25 m

Application : Airborne Particle Monitoring in Cleanrooms

Operating Voltage : 100240V AC

Power Supply : 100240V AC, 50/60 Hz



arrow